fbpx
Allen-Bradley Rockwell safety relay MSR127RP(440R-N23135)
Allen-Bradley Rockwell safety relay MSR127RP(440R-N23135)
Allen-Bradley Rockwell safety relay MSR127RP(440R-N23135)
Allen-Bradley Rockwell safety relay MSR127RP(440R-N23135)

Allen-Bradley Rockwell safety relay MSR127RP(440R-N23135)

Featured
1per day(Fixed)

Allen-Bradley Rockwell safety relay MSR127RP(440R-N23135)A Full Line of Single and Specialty Function RelaysSafety Relay, MSR127RP, 24V AC/DC, Manual Monitored, Removable, 22.5MM Housing Width, Infinite, One 2 N.C. Input, One LC Input, 3 Safety Outp ut, 1 N.C. Aux. Relay Output, CAT 4 RatedFor dependable fault detection that will minimise downtime and help you keep operations running efficiently, the 440R Minotaur MSR127RTP Single Function Safety Relays by Rockwell Automation are the ideal choice for your safety control system. The MSR family of relays are perfectly suited for relatively small safety applications and single zone control.Please contact me get more informationEmail:[email protected]/Whatsapp/Telegram:+8613667120925Website: www.cwlyautomation.com These versatile single function safety relays can be connected in 3 different input wiring configurations: 1NC, 2NC, or with two PNP connections from a light curtain. The MSR127RT checks for cross faults across the two inputs when connected in the 2NC configuration. The light curtain must perform the cross fault detection when the safety relay is connected to light curtains.The MSR127TP relay features an automatic/manual reset, which can be jumpered or changed to an unmonitored manual reset by the addition of a normally open switch in the monitoring loop. The MSR127RP unit has a monitored manual reset which offers checking of the output monitoring circuit.These devices are ideal for light curtain, E-stop or safety gate applications.Features and Benefits:

• Compact housing• Stop category 0 and Cross fault monitoring• Cat. 4 per EN954-1• Relays with monitored or automatic reset

• Removable terminals•Three NO (Normally Open) safety-rated outputs, one NC (Normally Closed) auxiliary contact

• Safety outputs feature independent and redundant internal contacts to support the safety function

• Auxiliary output is a non-safety output which can provide an external signal to indicate the status of the safety outputsRockwell Automation Monitoring Safety Relay, 230V AC Supply Voltage, 3 Safety Contacts – MSR127RP Series – 440R-N23133Prevent sudden faults from damaging your setup with this safety relay from Rockwell Automation.

It blocks output signals if a fault emerges in your electrical system to shut down the connected machinery and allow you to address the issue safely. With its single-function design, you can individually programme the relay to monitor for the faults you’re most concerned about. The relay needs a manual reset after tripping, ensuring that the circuit stays off while inspection and servicing take place for maximum personnel safety.

• Built-in LED indicators inform operators that the relay is activated and when a fault emerges, reducing the time spent on system inspections•

Supports single and dual-channel monitoring for a versatile component that suits smaller safety applications•

Switching time of 15ms provides a rapid response to stop critical faults before they become dangerous•

Compatible with a light curtain sensor to keep personnel and equipment safePlease contact me get more information.